Neutral Parametrization¶
ThermoWeave fits continuous neutral OpenCOSMO-RS parameters against the bulk
corpus evaluators. Every candidate is an in-memory Parametrization; no JSON
file is rewritten during optimization. The C++ legacy engine loads the required
molecules afresh for each distinct candidate. This is slower than reusing stale
profiles, but correct for preprocessing parameters such as Rav and
Rav_corr.
from thermoweave import (
CorpusObjective, FitParameter, Log, LossConfig, OptimizationConfig,
ParameterSpace, fit_parameters, load_parametrization,
)
base = load_parametrization("default_orca")
space = ParameterSpace([
FitParameter("Aeff", "parameters.Aeff", 4.0, 8.0),
# Bounds are physical; the C++ backend stores this as ln_alpha.
FitParameter("alpha", "parameters.ln_alpha", 0.2, 5.0, Log()),
])
objective = CorpusObjective(
corpus_paths,
component_database,
base,
space,
loss_config=LossConfig(
weights={"IDAC": 1.0, "AC": 1.0, "logK": 1.0,
"LLE_NIST": 1.0, "LLE_DECHEMA": 1.0,
"dGsolvation": 1.0},
scales={"IDAC": 1.0, "AC": 1.0, "logK": 1.0,
"LLE_NIST": 1.0, "LLE_DECHEMA": 1.0,
"dGsolvation": 1.0},
),
)
result = fit_parameters(
objective,
config=OptimizationConfig(method="Nelder-Mead", maxiter=200),
)
result.to_json("fit-result.json")
optimized = result.optimized_parametrization
optimized.to_json("optimized-parametrization.json")
The optimized parametrization file can be loaded again with the same
load_parametrization("optimized-parametrization.json") function. This
ThermoWeave v1 format stores the already-adapted C++ options/parameters exactly;
Backend JSON inputs continue to be delegated to the validated C++ loader.
Available serial methods are bounded Nelder-Mead, L-BFGS-B, and seeded
differential_evolution. The objective is the sum of weighted, scaled
per-property MSEs: IDAC/AC in ln(gamma), partition/LLE data in log10(K), and
dGsolvation in kcal/mol. Candidate scorer errors, non-finite predictions, or
changed scored-entry counts receive the configured failure value and cannot
improve a fit by dropping difficult records.
Canonical selectors include Aeff, alpha, CHB, CHBT, sigma_HB, Rav,
Rav_corr, f_corr, m_vdW, E_F_corr, numeric combinatorial fields, and
dGsolv calibration parameters. tau_Z(Z, lower, upper) defines an atomic
dGsolv tau parameter. Use explicit scientifically meaningful bounds.
Discrete switches, ion parameters, ME-PDH, reactions, VLE fitting, and parallel candidate evaluation are intentionally excluded from this first neutral fitter.